Si-tex ES502 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Navigatoren Si-tex ES502 herunter. Si-tex ES502 User manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - User Manual

User ManualCopyright 2008 Seiwa - Hong KongAll rights reserved. Printed in Italy. No part of this publication may be reproduced or distributed in any

Seite 2 - Important Information

12 User Manual Digital DepthReadout of the current bottom depth.Water TemperatureReadout of the current water temperature returned by the TEMP 1 senso

Seite 3 - Contents

13User ManualFishesFishes are represented as arcs because of the cone angle of the transducer.In fact as the boat passes over the fish the leading edg

Seite 4 - 6 User Manual

14 User Manual[MENU] + "PAGE" + [ENTER] + "FISH FINDER" + [ENTER]Fig. 2.2.1 - Fish Finder page selection by MenuCOLOR MAX 11/COLOR

Seite 5 - About this User Manual

15User ManualIn the picture below, the four soft keys are customized to select the four FishFinder page:Fig. 2.2.1.1 - Fish Finder page selection by S

Seite 6 - IF YOU NEED ASSISTANCE

16 User ManualThe ENTER keyPressing [ENTER] activates the Sensitivity menu (see Par. 3.1.1) that allowstuning the Gain, the Surface Noise Filter and

Seite 7 - 1. Overview

17User Manual2.2.4 Zoom pageTo display the zoomed Fish Finder page on the left half of the screen and the un-zoomed Fish Finder Echogram on the right

Seite 8 - ♦ Fish Symbol feature (*)

18 User Manual♦ if the focus (the active window) in on the Chart, the Main menu isshown. Pressing again [MENU] opens the Fish Finder Setup menu andmov

Seite 9 - 2. Fish Finder

19User ManualWhen in Split/Combo pages, the active view is highlighted by a focus (Yellowframe). The keyboard commands are related to that focused vie

Seite 10

20 User ManualThe STC Soft KeyThe [STC] changes the STC value between OFF/SHORT/MID/LONG. The currentvalue of STC is shown on a window right over the

Seite 11

21User Manual3. Setup your Fish Finder3.1 FISH FINDER SETUP MENUThe Fish Finder Setup menu provides access to additional functions, setup andlayout/da

Seite 12 - 2.2.1.1 Selection by Soft Key

4 User ManualImportant InformationCAUTION♦ Please read through this manual before the first operation. If you have anyquestions, please contact the Co

Seite 13 - 2.2.2 Fish Finder Full page

22 User Manual3.1.5 ShiftThis option is available only when Range Mode is Manual and it is disabled in AutoRange and Bottom Lock Mode.[MENU] + "S

Seite 14 - 2.2.3 Dual Frequency page

23User Manual3.1.9.5 STC StrenghIf STC is Custom, it is possible to change the Strength of the Sensitivity TimeConstant.3.1.9.6 Surface Noise FilterTh

Seite 15 - 2.2.5 Chart/Fish page

24 User Manualbetween Primary and External.3.1.11 Transducer SetupThe Transducer Setup menu contains settings that does not require frequentchanges.[M

Seite 16

25User Manual3.1.12.2 Depth WaterTriggers an alarm when depth becomes deeper than the value set.3.1.12.3 Temperature UpperTriggers an alarm when the t

Seite 18 - 2.5.1 The System Update menu

27User Manual4. ES502This chapter provides instructions to assist in planning the installation of the ES502.4.1 TECHNICAL SPECIFICATIONS♦ Display Colo

Seite 19 - 3. Setup your Fish Finder

28 User Manual♦ ES502 (with Power Serial and optional devices cables already connected)♦ Fuse 5 Amp. + fuseholder♦ User Manual4.2 DIMENSIONS174.30mm [

Seite 20 - 3.1.9 Sensitivity

29User ManualFig. 4.3.1 - The ES502 Installation♦ Fix the ES502 to the mounting location using the four screws (holesdiameter 4 mm), see Fig. 4.3.1.

Seite 21 - 3.1.10.5 Water Temperature

30 User Manualplotter a warning window is shown, select "CANCEL" and press [ENTER]:the ES502 is not sending any signal.4.5 EXTERNAL CONNECTI

Seite 22 - 3.1.12 Alarms

31User Manual4.6 POWER SUPPLY WIRING DIAGRAMWe recommended the installation of a switch and a (5A) fuse in the positive DCsupply to the ES502. The ES5

Seite 23

5User ManualContentsImportant Information ... 4CAUTION ...

Seite 24 - 26 User Manual

32 User Manual4.7 SUGGESTED PLOTTER CONNECTIONSThe following are suggested "Fish Finder - chart plotter" connections.NOTE On the chart plott

Seite 25 - 4. ES502

33User Manual5. TransducersThe transducer is a device that transmits and receives sound waves into thewater. The active component inside the transduce

Seite 27 - 4.4 STATUS LED

35User Manual6. Frequently Asked Questions6.1 How can I disconnect the cables from the ES502 in caseI need to do so for the installation?♦ Open the ES

Seite 28 - 4.5 EXTERNAL CONNECTIONS

36 User Manual6.2 How can I set optimal operating parameters.Optimal operating parameters can be set accordingly with the intended use of theFish Find

Seite 29 - Chart Plotter

37User Manual6.7.3 Auto-range fails in very deep waters displaying a digital veryshallow depth readout. What should I do?The Fish Finder capability to

Seite 30 - 32 User Manual

38 User Manualtrying to set optimal GAIN value for each situation. To avoid this it is advisable toswitch to MANUAL GAIN mode and fine tune the GAIN t

Seite 31 - 5. Transducers

39User ManualAnalytical IndexAA-Scope ... 9, 12About ...

Seite 32 - 34 User Manual

40 User ManualSensitivity ... 20, 22Sensitivity menu ... 16Sensitivity Time

Seite 33 - Rubber Gasket

41User ManualCERTIFICATE OF LIMITED WARRANTYProviding you present a valid proof of purchase, SI-TEX warrants all parts of each new product againstdefe

Seite 34

6 User Manual3.1.10 Display Setup ... 233.1.10.1 Color Settings ONLY FOR C

Seite 35

7User ManualAbout this User ManualINTRODUCTIONThe chart plotter combined with the sonar performance of the Fish Finder is oneof the most advanced mari

Seite 36 - 38 User Manual

8 User ManualCOLOR MAX SEALINK I 7" Sunlight Readable WVGA Color Display S4igSW8wcInternal GPS ReceiverCOLOR MAX PRO 11" Sunlight Readable C

Seite 37 - Analytical Index

9User Manual1. OverviewThe Fish Finder consists of a high power transmitter, sensitive receiver and atransducer. The Fish Finder sends an electrical p

Seite 38 - 40 User Manual

10 User Manual♦ Noise Filter♦ Fish Symbol feature (*)♦ Automatic Setup Transducer. Recognition for devices (automatictransducer identification and p

Seite 39

11User Manual2. Fish FinderThis chapter is intended to help you understand how the chart plotter with theFish Finder connected operates to improve you

Kommentare zu diesen Handbüchern

Keine Kommentare